Pharma-line is a high-quality shell & tube heat exchanger especially developed to meet the high hygienic demands of the pharmaceutical industry. The design of the Pharma-line makes it easy to drain and clean, and there is no risk of cross contamination associated with conventional heat exchangers. The documentation on a heat exchanger in the pharmaceutical industry is equally important as the hardware so the Pharma-line comes together with a high quality documentation package as standard and most specials are available upon request. Applications The unit is designed to work under highest hygienic conditions in applications such as WFI, PW and heating/cooling of pharmaceutical products. Design and working principles The product media flows through a bundle of seamless, electropolished tubes. The service media flows outside the tubes in cross flow. At the end the tubes are fastened by two tube sheets (see Fig. 1) acting as leakage indicators and prevent cross contamination between the product and the service media. The Pharma-line can be installed either horizontally or vertically depending on the duty or space. For an easy installation, lifting and mounting devices are welded on the unit. Thermal fatigue caused by large temperature changes are taken up by the U-bend in 2-pass units and by a welded in bellow in straight units.

Special features . Seamless tubes . Double tube-sheets to protect against service media leaking into the product. . Completely drainable. . No dead spots in the tubes. . Designed according to FDA and cGMP. . Flexibledesign. Standard range A standard range of U-tube designed Pharma-line is available that suit most applications.
Technical data of standard units Heat transfer area 0-5 m2 Design temperature 180°C Design pressure 10 barg/FV Materials 316L and FDA approved EPDM, USP class VI Connections Tri-clamp on tube side and flanges on utility side PV codes PED and ASME VIII (U-stamp on request) Welding according to ASME IX and EN-288-3, EN 287-1 Surface finish, product wetted parts Ra < 0,5 μm Insulation available in mineral wool (ASTM C 975) Documentation at delivery: Drawing, list of welders and weld license, material certificate, liquid penetration test report, surface treatment report, dimension control report, pressure test report, installation, operation and maintenance manual, CE-conformity documentation. Custom-made Other designs and documentation of Pharma-line are available on request.
|